Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.071
Filtrar
1.
Turk J Ophthalmol ; 54(2): 56-62, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644780

RESUMO

Objectives: Determining the accuracy of cycloplegic refractive error measurements made with the Spot Vision Screener (SVS, Welch Allyn Inc, Skaneateles Falls, NY, USA) is important for refractive assessment of uncooperative patients during optometric examinations. This study compared cycloplegic refractive errors measured by SVS and tabletop autorefractometer to cycloplegic retinoscopy in children. Materials and Methods: Eighty-eight eyes of 44 subjects were examined in the study. Refractive error measurements were obtained under cycloplegia using retinoscopy, SVS, and Nidek ARK-530 tabletop autorefractometer (ARK-530, Nidek, Japan). Spherical and cylindrical values, spherical equivalents (SE), and Jackson cross-cylinder values at axes of 0° (J0) and 45° (J45) were recorded. Correlations between methods were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: The mean age was 7 years (range: 6 months-17 years). Sixteen (36%) of the subjects were female and 28 (64%) were male. For SE there was excellent agreement between retinoscopy and SVS (ICC: 0.924) and between retinoscopy and tabletop autorefractometer (ICC: 0.995). While there was a moderate correlation between retinoscopy and SVS for cylindrical values (ICC: 0.686), excellent correlation was detected between retinoscopy and autorefractometer (ICC: 0.966). J0 and J45 crosscylinder power values were not correlated between retinoscopy and SVS (ICC: 0.472) or retinoscopy and tabletop autorefractometer (ICC: 0.442). Retinoscopy was correlated with both SVS and tabletop autorefractometer for all parameters within ±1.96 standard deviations in Bland-Altman analysis. Conclusion: Cycloplegic retinoscopy is the gold standard for refractive error measurement in the pediatric population. However, it requires time and experienced professionals. This study revealed moderate to good agreement between SVS and retinoscopy, with better agreement in spherical errors than cylindrical errors. Although the SVS is intended for screening programs, it may also be useful in the pediatric eye office to estimate spherical refractive error in uncooperative patients.


Assuntos
Refração Ocular , Erros de Refração , Retinoscopia , Seleção Visual , Humanos , Feminino , Masculino , Criança , Retinoscopia/métodos , Adolescente , Pré-Escolar , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Lactente , Reprodutibilidade dos Testes , Seleção Visual/instrumentação , Seleção Visual/métodos , Midriáticos/administração & dosagem
2.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
3.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658894

RESUMO

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Assuntos
Terapia a Laser , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Resultado do Tratamento , Desenho de Prótese , Extração de Catarata/métodos , Seguimentos
4.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651698

RESUMO

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Esclera/cirurgia , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Retalhos Cirúrgicos , Técnicas de Sutura , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia
6.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527448

RESUMO

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Assuntos
Câmara Anterior , Subluxação do Cristalino , Lentes Intraoculares , Refração Ocular , Humanos , Masculino , Feminino , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/fisiopatologia , Adulto , Acuidade Visual , Estudos Retrospectivos , Óptica e Fotônica , Implante de Lente Intraocular/métodos , Biometria/métodos , Idoso de 80 Anos ou mais
7.
J Cataract Refract Surg ; 50(5): 492-497, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237070

RESUMO

PURPOSE: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. SETTING: National Hospital Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. RESULTS: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.


Assuntos
Comprimento Axial do Olho , Biometria , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Estudos Retrospectivos , Biometria/métodos , Masculino , Feminino , Tomografia de Coerência Óptica/métodos , Refração Ocular/fisiologia , Implante de Lente Intraocular , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia
8.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
9.
Cornea ; 41(4): 450-455, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244625

RESUMO

PURPOSE: The purpose of this study was to investigate 3-year changes in keratoconus (KC) indices to determine the indicators of KC progression compared with age-related changes in children aged 6 to 12 years. METHODS: In this report of the Shahroud Schoolchildren Eye Cohort Study, KC was diagnosed based on vision, refraction, tomography, and slitlamp examination findings. KC progression was defined as changes in refractive astigmatism or zonal maximum keratometry (Zonal Kmax-3 mm). Then, 3-year changes (Δ) in vision, refraction, and tomographic indices were compared between progressive KC and normal eyes. The best set of ∆parameters for distinguishing KC progression from age-related changes were determined using the area under curve (AUC). RESULTS: Eighteen KC eyes and 10,422 normal eyes were analyzed. All KC cases showed progression after 3 years. Δindices were statistically different between the 2 groups except corrected distance visual acuity, anterior radius of curvature, irregularity index, and KC percentage index. The best Δindices, in descending order of AUC value, were index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry (all AUC > 0.9), followed by inferior-superior asymmetry, index of surface variance, minimum corneal thickness, index of height asymmetry, KC index, posterior radius of curvature, and Belin/Ambrósio total Deviation (AUC = 0.8-0.9). CONCLUSIONS: According to our findings, changes in index of height decentration, Zonal Kmax-3 mm, refractive astigmatism, single point Kmax, and index of vertical asymmetry are the best indices for detecting KC progression in children younger than 12 years.


Assuntos
Ceratocone/diagnóstico , Envelhecimento/fisiologia , Fenômenos Biomecânicos , Criança , Córnea/fisiopatologia , Paquimetria Corneana , Topografia da Córnea , Progressão da Doença , Feminino , Humanos , Ceratocone/epidemiologia , Ceratocone/fisiopatologia , Masculino , Prevalência , Curva ROC , Refração Ocular/fisiologia , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia
10.
Invest Ophthalmol Vis Sci ; 63(2): 16, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35133400

RESUMO

Purpose: The purpose of this study was to evaluate the impact of full-spectrum light-emitting diodes mimicking sunlight (Sunlike LEDs) on ocular growth and refractive error development in a chicken model of myopia. Methods: One-day old chicks (n = 39) were distributed into 3 groups and raised for 28 days in isoluminant (approximately 285 lux) fluorescent (n = 18, [FL-4000], correlated color temperature [CCT] = 4000 K) or Sunlike LED (n = 12, [SL-4000], CCT = 4000 K; n = 9, [SL-6500], CCT = 6500 K) white lighting environments. Form-deprivation myopia was induced monocularly from day 1 post-hatching (D1) until D14. On D14, form deprivation was halted and the recovery of form-deprived (FD) eyes was monitored until D28. Axial length (AL), refraction, choroidal thickness, and anterior chamber depth were measured in vivo on D1, D7, D14, D22, and D28. Differences in outcome measures between eyes and groups were compared using 2-way repeated-measures ANOVA. Results: AL and myopic refraction of FD eyes increased similarly among groups during form-deprivation. FD eyes of animals raised under SL-4000 (D22: P < 0.001 and D28: P < 0.001) and SL-6500 (D22: P = 0.006 and D28: P < 0.001) recovered faster from axial elongation compared with animals raised under FL-4000. The refractive status of FD eyes reared under SL-6500, not under FL-4000 or SL-4000, was similar to control eyes on D28 (P > 0.05). However, SL-4000 and SL-6500 exhibited similar refraction on D28 than FL-4000 (P > 0.05). Choroidal thickness was significantly greater in FD eyes of chickens raised under SL-6500 than in animals raised under FL-4000 (P = 0.03). Conclusions: Compared to fluorescent light, moderate intensities of full-spectrum Sunlike LEDs can accelerate recovery from form-deprivation myopia in chickens, potentially through a change in the choroid-mediated pathway.


Assuntos
Cor , Luz , Miopia/fisiopatologia , Recuperação de Função Fisiológica/fisiologia , Refração Ocular/fisiologia , Privação Sensorial , Temperatura , Animais , Animais Recém-Nascidos , Comprimento Axial do Olho/fisiopatologia , Galinhas , Corioide/patologia , Modelos Animais de Doenças , Miopia/etiologia , Tamanho do Órgão , Retina/patologia
11.
Invest Ophthalmol Vis Sci ; 63(2): 2, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35103751

RESUMO

Purpose: To explore the relationship of color vision deficiency with myopia progression and axial elongation in Chinese primary school children during a five-year cohort study. Methods: A total of 2849 grade 1 students (aged 7.1 ± 0.4 years) from 11 primary schools were enrolled and followed up for five years. Cycloplegic autorefraction and axial length were measured annually. Color vision testing was performed using Ishihara's test and the City University color vision test. Results: The prevalence of color vision deficiency was 1.68%, with 2.81% in boys and 0.16% in girls. Color-deficient cases consisted of 91.6% deutan and 8.3% protan. Over the five years, the cumulative incidence of myopia was 35.4% (17/48) in the color-vision deficiency group, which was lower than the 56.7% (1017/1794) in the color normal group (P = 0.004). Over the five-year study period, the change in spherical equivalent refraction in the color vision-deficiency group (-1.81 D) was also significantly lower than that in the color normal group (-2.41 D) (P = 0.002). Conclusions: The lower incidence and slower progression of myopia in children with color-vision deficiency over the five-year follow-up period suggest that color-deficient individuals are less susceptible to myopia onset and development.


Assuntos
Defeitos da Visão Cromática/etiologia , Visão de Cores/fisiologia , Miopia/complicações , Refração Ocular/fisiologia , Comprimento Axial do Olho , Criança , Pré-Escolar , China/epidemiologia , Defeitos da Visão Cromática/epidemiologia , Defeitos da Visão Cromática/fisiopatologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Morbidade/tendências , Miopia/epidemiologia , Miopia/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo
12.
Invest Ophthalmol Vis Sci ; 63(2): 22, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35147660

RESUMO

Purpose: To investigate the impact of the size and location of waterclefts (WC), which are one of several cataract subtypes, on visual function by optical simulation analysis. Methods: An optical simulation software (CODE V) was used to develop a schematic eye model and several sizes of WC central and peripheral types that were located below the anterior and posterior subcapsules of the crystalline lens, and analyses of refraction, higher-order aberrations (HOA), and the modulation transfer function (MTF) were performed. Results: An increase in the WC size increased the refraction and HOA and decreased the MTF. The impact of the WC below the posterior subcapsule on the visual function was more enhanced than that below the anterior subcapsule. Large WC demonstrated a remarkable hyperopic shift in refractive power as well as an increase in HOA. The MTF decreased slightly with increasing WC size at a spatial frequency of 20 cycles/mm, and it decreased remarkably at 60 cycles/mm. Conclusions: The impact on the visual function increased with increasing WC size. It was revealed that eyes with WC below the posterior subcapsule are more hyperopic than those with WC below the anterior subcapsule, and the former have a higher HOA and lower MTF than the latter.


Assuntos
Catarata/fisiopatologia , Simulação por Computador , Erros de Refração/fisiopatologia , Acuidade Visual/fisiologia , Idoso , Catarata/diagnóstico por imagem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade , Refração Ocular/fisiologia
13.
Invest Ophthalmol Vis Sci ; 63(2): 28, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195683

RESUMO

Purpose: Children with Down's syndrome (DS) are known to have poorer visual acuity than neurotypical children. One report has shown that children with DS and nystagmus also have poor acuity when compared to typical children with nystagmus. What has not been established is the extent of any acuity deficit due to nystagmus and whether nystagmus affects refractive error within a population with DS. Methods: Clinical records from the Cardiff University Down's Syndrome Vision Research Unit were examined retrospectively. Binocular visual acuity and refraction data were available for 50 children who had DS and nystagmus and 176 children who had DS but no nystagmus. Data were compared between the two groups and with published data for neurotypical children with nystagmus. Results: The study confirms the deficit in acuity in DS, compared to neurotypical children, of approximately 0.2 logMAR and shows a deficit attributable to nystagmus of a further 0.2 logMAR beyond the first year of life. Children with both DS and nystagmus clearly have a significant additional impairment. Children with DS have a wide range of refractive errors, but nystagmus increases the likelihood of myopia. Prevalence and axis direction of astigmatism, on the other hand, appear unaffected by nystagmus. Conclusions: Nystagmus confers an additional visual impairment on children with DS and must be recognized as such by families and educators. Children with both DS and nystagmus clearly need targeted support.


Assuntos
Síndrome de Down/fisiopatologia , Nistagmo Patológico/fisiopatologia , Erros de Refração/fisiopatologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , Astigmatismo/fisiopatologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Nistagmo Patológico/diagnóstico , Refração Ocular/fisiologia , Estudos Retrospectivos , Testes Visuais , Visão Binocular/fisiologia
14.
Opt Express ; 30(2): 2078-2088, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35209355

RESUMO

A foveated display is a technology that can solve the problem of insufficient angular resolution (relative to the human eye) for near-eye display. In a high-resolution foveated display, a beam steering element is required to track the human gaze. An electrowetting prism array is a transmissive non-mechanical beam steering device, that allows a light and compact optical system to be configured and a large aperture possible. However, the view is obstructed by the sidewall of the prism array. When the size of the cell prism is 7mm, the prism array has an 87% fill-factor. To push the fill-factor to 100%, the cell prisms were magnified using a lens array. Image processing was performed such that the image produced by the lens array was identical to the original. Beam steering by refraction is accompanied by chromatic dispersion, which causes chromatic aberration, making colors appear blurry. The refractive index condition to reduce chromatic dispersion was obtained using the doublet structure of the electrowetting prism. The chromatic dispersion was reduced by 70% on average.


Assuntos
Eletroumectação/instrumentação , Fóvea Central/fisiologia , Imagem Óptica/instrumentação , Óptica e Fotônica , Animais , Humanos , Processamento de Imagem Assistida por Computador/métodos , Refração Ocular/fisiologia
15.
Invest Ophthalmol Vis Sci ; 63(1): 3, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34982147

RESUMO

Purpose: Amblyopia is diagnosed as a reduced acuity in an otherwise healthy eye, which indicates that the deficit is not happening in the eye, but in the brain. One suspected mechanism explaining these deficits is an elevated amount of intrinsic blur in the amblyopic visual system compared to healthy observers. This "internally produced blur" can be estimated by the "equivalent intrinsic blur method", which measures blur discrimination thresholds while systematically increasing the external blur in the physical stimulus. Surprisingly, amblyopes do not exhibit elevated intrinsic blur when measured with an edge stimulus. Given the fundamental ways in which they differ, synthetic stimuli, such as edges, are likely to generate contrasting blur perception compared to natural stimuli, such as pictures. Because our visual system is presumably tuned to process natural stimuli, testing artificial stimuli only could result in performances that are not ecologically valid. Methods: We tested this hypothesis by measuring, for the first time, the perception of blur added to natural images in amblyopia and compared discrimination performance for natural images and synthetic edges in healthy and amblyopic groups. Results: Our results demonstrate that patients with amblyopia exhibit higher levels of intrinsic blur than control subjects when tested on natural images. This difference was not observed when using edges. Conclusions: Our results suggest that intrinsic blur is elevated in the visual system representing vision from the amblyopic eye and that distinct statistics of images can generate different blur perception.


Assuntos
Ambliopia/fisiopatologia , Erros de Refração/fisiopatologia , Percepção Visual/fisiologia , Adulto , Idoso , Esotropia/fisiopatologia , Exotropia/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Limiar Sensorial/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
16.
Invest Ophthalmol Vis Sci ; 63(1): 8, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34989760

RESUMO

Purpose: To determine the annual incidences and rates of progression of myopia and high myopia in Chinese schoolchildren from grade 1 to grade 6 and explore the possible cause-specific risk factors for myopia. Methods: From 11 randomly selected primary schools in Anyang city, central China, 2835 grade 1 students were examined with annual follow ups for 5 years. Students were invited to undergo a comprehensive examination, including cycloplegic autorefraction, ocular biometry, and standardized questionnaires. Results: The mean spherical equivalent refraction decreased substantially from +0.94 ± 1.03 diopter (D) in grade 1 to -1.37 ± 2.08 D in grade 6, with rapid annual myopic shifts, especially for students in grades 3 through 6 (-0.51 to -0.59 D). The prevalence of myopia increased substantially, with the yearly incidence of myopia increasing from 7.8% in grade 1 and 2 to 25.3% in grades 5 and 6, and the incidence of high myopia increased from 0.1% to 1.0%. The 5-year incidence of myopia was lowest among children who has a baseline spherical equivalent refraction of greater than +2.00 D (4.4%), and increased to nearly 92.0% among children whose baseline spherical equivalent refraction was 0.00 to -0.50 D. The incidence of myopia was higher in children who had less hyperopic baseline refraction, two myopic parents, longer axial length, deeper anterior chamber, higher axial length-corneal radius of curvature ratio, and thinner lenses. Conclusions: Both the annual incidence and progression rates of myopia and high myopia were high in Chinese schoolchildren, especially after grade 3. Hyperopic refraction of children should be monitored before primary school as hyperopia reserve to prevent the onset of myopia and high myopia.


Assuntos
Povo Asiático/estatística & dados numéricos , Miopia/diagnóstico , Miopia/epidemiologia , Biometria , Criança , China/epidemiologia , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Humanos , Incidência , Masculino , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/epidemiologia , Prevalência , Refração Ocular/fisiologia , Fatores de Risco , Estudantes , Testes Visuais
17.
Invest Ophthalmol Vis Sci ; 63(1): 2, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34978559

RESUMO

Purpose: Our studies in mouse eye lenses demonstrate that ephrin-A5 and EphA2 are needed for normal epithelial cells and lens transparency. We sought to determine whether EphA2 and ephrin-A5 are important for lens morphometrics, nucleus formation, and refractive index. Methods: We performed tissue morphometric measurements, electron microscopy, Western blots, and interferometric measurements using an X-ray synchrotron beam source to measure the gradient of refractive index (GRIN) to compare mouse lenses with genetic disruption of EphA2 or ephrin-A5. Results: Morphometric analysis revealed that although there is no change in the overall lens volume, there is a change in lens shape in both EphA2-/- lenses and ephrin-A5-/- lenses. Surprisingly, EphA2-/- lenses had small and soft lens nuclei different from hard lens nuclei of control lenses. SEM images revealed changes in cell morphology of EphA2-/- fiber cells close to the center of the lens. Inner EphA2-/- lens fibers had more pronounced tongue-and-groove interdigitations and formed globular membrane morphology only in the deepest layers of the lens nucleus. We did not observe nuclear defects in ephrin-A5-/- lenses. There was an overall decrease in magnitude of refractive index across EphA2-/- lenses, which is most pronounced in the nucleus. Conclusions: This work reveals that Eph-ephrin signaling plays a role in fiber cell maturation, nuclear compaction, and lens shape. Loss of EphA2 disrupts the nuclear compaction resulting in a small lens nucleus. Our data suggest that Eph-ephrin signaling may be required for fiber cell membrane reorganization and compaction and for establishing a normal GRIN.


Assuntos
Núcleo do Cristalino/crescimento & desenvolvimento , Receptor EphA2/fisiologia , Refração Ocular/fisiologia , Animais , Membrana Celular/metabolismo , Membrana Celular/ultraestrutura , Efrina-A5/fisiologia , Técnicas de Genotipagem , Interferometria , Núcleo do Cristalino/metabolismo , Núcleo do Cristalino/ultraestrutura , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica de Varredura , Forma das Organelas/fisiologia , Reação em Cadeia da Polimerase em Tempo Real , Transdução de Sinais/fisiologia , Raios X
19.
Cornea ; 41(3): 359-362, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34864796

RESUMO

PURPOSE: The purpose of this study was to report a case of bilateral ectasia 3 years after small incision lenticule extraction (SMILE) in a patient with normal preoperative topography of the right eye and abnormal topography of the left eye. METHODS: This study was a case report. RESULTS: A 22-year-old man developed bilateral corneal ectasia after SMILE. The preoperative corneal topography of the right eye was unremarkable, with a minimum corneal thickness of 511 µm in the right eye, and the abnormal corneal topography of the left eye revealed a risk factor for developing ectasia, with a minimum corneal thickness of 514 µm in the left eye. The refractive error was -4.50 to 3.50 × 10 degrees in his right eye and -4.25 to 3.50 × 0 degrees in his left eye with a best-corrected visual acuity of 20/20. An uncomplicated SMILE was performed; after his last follow-up visit at 1 month, the patient was lost to follow-up for 3 years. After that time, he presented with visual loss with left predominance. Bilateral ectasia was diagnosed through corneal topography, and crosslinking was performed in both eyes. CONCLUSIONS: There are a very few reports of corneal ectasia after SMILE with normal preoperative topography.


Assuntos
Doenças da Córnea/etiologia , Substância Própria/patologia , Topografia da Córnea/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Miopia/cirurgia , Complicações Pós-Operatórias/etiologia , Refração Ocular/fisiologia , Doenças da Córnea/diagnóstico , Substância Própria/cirurgia , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Adulto Jovem
20.
Cornea ; 41(4): 518-537, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34839335

RESUMO

PURPOSE: The aims of this meta-analysis were to evaluate the results of intracorneal ring segments (ICRSs) and MyoRing in the management of corneal ectasia and to compare the clinical outcomes and complication rates between mechanical and femtosecond (FS) laser-assisted surgery. METHODS: An online electronic search was performed for pre-post studies published until April 2020. Uncorrected distance visual acuity, corrected distance visual acuity, sphere, cylinder, spherical equivalent, steep, flat, and mean keratometry values were considered as outcomes. Weighted mean difference with 95% confidence interval was used as a pooled estimation of intervention efficacy. RESULTS: Of 1484 potentially related studies, 115 studies were finally included in the meta-analysis. Findings of this meta-analysis demonstrated considerable improvement in visual, refractive, and keratometric outcomes in all ICRS models and MyoRing. Intrastromal tunnel creation with both methods yielded similar results. Complication rates were without exception higher when mechanical dissection was used. CONCLUSIONS: ICRS and MyoRing are appropriate treatment options for patients with corneal ectasia. Both techniques for tunnel creation are efficacious in achieving good visual, keratometric, and refractive results. Mechanical intrastromal tunnel creation is associated with much higher complication rates when compared with FS laser-assisted technique.


Assuntos
Substância Própria/cirurgia , Dissecação/métodos , Ceratocone/cirurgia , Terapia a Laser/métodos , Próteses e Implantes , Implantação de Prótese/métodos , Humanos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Polimetil Metacrilato , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...